Product Description
Steam Sterilization Chemical Indicator Card, Pressure Steam Sterilization Disinfection Indicator Card, Level 4 Medical Steam Indicator Card, Usage Method
1. Place the steam sterilization indicator card in the center of the standard test package or item, with one end of the card printed with the indicator. Place it in the middle of the item package, and the indicator card should be placed at the intersection of the hard container or at least two diagonals, or in the most difficult to sterilize area. For each sterilization process, place one indicator card in each large bag and in the difficult to sterilize area. Wrap the indicator card with gauze or kraft paper to prevent it from getting damp and affecting the result judgment.
2. According to the routine sterilization operation, when sterilized with saturated steam at 121 (+-2) ° C, the indicator card color block changes from yellow to black, indicating that the sterilization package has been sterilized; If the color change on the indicator card is uneven or there is no change in color, it indicates that the package has not been sterilized. Under steam conditions at 121 ºC for 15 minutes, the indicator color block changes from yellow to black. Under steam conditions at 132 ºC for 3.5 minutes, the indicator color block changes from yellow to black. Steam sterilization chemical indicator card, pressure steam sterilization disinfection indicator card, level 4 medical steam indicator card, application scope Steam sterilization indicator card pressure steam indicator card level 4 high pressure disinfection indicator card is used for exhaust and pre vacuum disinfection pots/EO (ethylene oxide) sterilization pots. Indicate whether the sterilization package has undergone the pressure steam sterilization process, determine the sterilization effect, and also be used for pressure steam sterilization indicator effect detection and judgment.
material |
Paper |
color |
beige become black |
size |
160mm*200 etc. |
inner pack |
250pcs/box |
OEM |
available |
package |
100boxes/carton |
certificate |
ISO13485&CE |
indicators |
EO & STEAM |
Steam Sterilization Chemical Indicator Card Pressure Steam Sterilization Disinfection Indicator Card Level 4 Medical Steam Indicator Card Structure and Performance
This product uses imported paper as the substrate, chemicals, color reagents, and their auxiliary materials to make ink, which is printed on special cardboard. The indicator color block changes from yellow to black under appropriate temperature, humidity, and pressure conditions, so as to quickly and intuitively reflect whether the sterilized item has been sterilized. The color after sterilization is not easy to fade.
The steam sterilization indicator card, pressure steam indicator card, and level 4 high-pressure disinfection indicator card are specifically designed to be pasted on the outside of the package to be sterilized, indicating whether the package has undergone high-pressure steam sterilization treatment to prevent mixing with unsterilized packages.
Steam Sterilization Chemical Indicator Card, Pressure Steam Sterilization Disinfection Indicator Card, Level 4 Storage Method and Precautions
When placing the item package, do not place it near the inner wall of the cabinet, and do not directly attach the indicator card to hard surfaces such as metal or glass that are prone to condensation. Also, do not use it inside infusion bottles, tubes, barrels, or other equipment to prevent the package from becoming damp and the chemical indicator card from being soaked by condensation, which will cause the thermal sensitive material of the indicator to lose accuracy.
The saturated vapor pressure should be ≥ 0.3Mpa. Insufficient saturated vapor pressure during transportation, or a decrease in saturated vapor pressure and vacuum degree due to a small amount of air leakage, can all result in inadequate discharge of cold air. When using pipelines for air delivery, if the exposed distance of the steam delivery pipeline is long, condensation water will be generated, which will increase the saturated steam moisture content and affect the sterilization effect. Do not use covered ceramic or glass containers for sterilization, as this may affect the entry of saturated steam and cold air, leading to sterilization failure.
When the temperature inside the cabinet is low or the action time is insufficient, it will cause sterilization failure.
This product should be stored at room temperature of 15 ° C~30 ° C, with a relative humidity of 50%, and should not be dampened.
Avoid light (including sunlight, fluorescent lamps, and ultraviolet disinfection lights), moisture, and avoid getting damp;
This product should not come into contact with corrosive gases such as acid and alkali, and should not be mixed with contaminated or toxic chemicals to avoid affecting the color rendering efficiency of the indicator.
If the indicator mark of the product changes color, do not use it.
Used indicator cards with discolored reagent parts should not be burned with fire to prevent dust generation.
Detailed Photos
- The steam sterilization chemical indicator card is made of imported medical cardboard, which is non-toxic and environmentally friendly, with a smooth surface and a hard texture. Steam sterilization chemical indicator card, pressure steam sterilization disinfection indicator card, level 4 medical steam indicator card, shelf life. This product is valid for 18 months from the date of production.
- 250 Pouches/Box
- 100 Boxes/Case
- Steam Sterilization Chemical Indicator Card Pressure Steam Sterilization Disinfection Indicator Card Level 4 Medical Steam Indicator Card Product Usage Steam indicator cards are widely used for testing sterilization effectiveness in industries such as hospitals, pharmaceuticals, food, health products, and beverages
Steam Sterilization Chemical Indicator Card Pressure Steam Sterilization Disinfection Indicator Card Level 4 Medical Steam Indicator Card Product Characteristics This product is advanced in technology, stable in performance, scientific in use, and convenient in use. It integrates three elements of temperature and time, steam purity, and sterilization. It is accurate, intuitive, and economical
Class 4 Steam Indicator Dual Strips
- Designed for steam sterilisation at 134 degrees 3.5 min.
- Dual strips can be divided into 2 pieces.
- Water-based, non-toxic, leaf free indicator.
- Clear and accurate colour change from PINK to DARK colour.
- Comply with ISO11140 standards.
Other Medical Consumables
Certifications
Company Profile
WE HAVE OWNED OURSELVES FACTORY IN 2015, THERE ARE 100 SQUARE METERS IN HEFEI OFFICE AND 100000 SQUARE METERS IN SHAN DONG FACTORYIS ONE OF THE MOST PROFESSIONAL DISPOSABLE DENTAL PRODUCTS' SUPPLIER IN CHINA.
For now, we can supply :
sterilization pouches & rolls, dental bibs, saliva ejectors, mixing tip, face masks, surgical gowns, face shield, dental kit, cheek tray, plishing brush, micro brush applicator, barrier film, alcohol pad swab, oral foam swab, mob clip cap, surgical blade,Irrigation needle, anaesthesia
needle, Ortho prosthesis box, cotton roll, air water tip, dental Dappen cup, Endo measure block, mixing tip, Prophylaxis Brushes, cheek retractors, mouth gags open my mouth, Impression tray, Dental Wedge, Mixing spatula, Dental kits(more in one), Medical face shield, Goggles, spectacle face visor, all kind of shoe covers and gowns, Plastic Tray, alginate, Endo Ring Foam Refill .
Our Advantages
Looking forward to cooperating with you in the future ......